Braemar Homes
Village Green, Los Angeles, California
Some
improvements include a single air handling unit within the building
enclosure that provides both heating and cooling, an independent supply
ventilation system, placing the ductwork in the conditioned space,
creating an air flow retarder system through glued gypsum board, and high
performance glazing. Results show a 40% reduction in heating, cooling and
domestic hot water costs could be achieved for little or no additional
cost. The models also exceed required airtightness standards.

Solar panels (left) | Model living room (center) | Walking distance to
public transportation (right)
The Lee Group and Braemar Urban Ventures was
awarded the 2000 Gold Energy Value Housing Award for Hot Climate /
Affordable Housing and Innovative/Advanced Housing.
 |